Oil and Gas Jobs:Electrical/Instrument Supervisor

Type:Contract
Location:Nigeria
Region:
Required Residency:British
Posted by:Taylor Recruitment Ltd
Expiry Date:09 May 2011

Job Description:
The ideal candidate will have commissioning & installation knowledge. He would be required to first review the drawings and go onboard to install them so software knowledge such us ABB or DCS is a plus.
It is a development project that includes the tie-back of 2 subsea wells and the refurbishment to a current FPSO.
We are in need of a commissioning engineer and an electrical/instrument supervisor. Both positions will be assigned onshore and an offshore rates since they would be required to go offshore on a periodic basis for the installation process of the work.
Location Port Harcourt Base, NIGERIA
Start date August 2011
Working days per week 6 days
Working hours per day 10 hours
Rotation 75 days working on site / 21 days of vacation
Accommodation Camp accommodations
Salary Onshore: 350 GBP Offshore: 375 GBP
Flight Class Economy
Medical benefits provided as per company standards

Required Skills: Electrical, Supervisor, Instrument

APPLY

Share

Related posts:

  1. Swift oil and gas Jobs Asia/Far East: ICAPS Construction Instrument Supervisor
  2. Electrical / Instrument Designer at SPIE Oil and Gas
  3. KCA DEUTAG AFRICA JOBS : Maintenance Supervisor – Electrical
  4. Swift Oil and Gas Jobs: Electrical Supervisor (Hot Job)
  5. Lead Planner at Swift Worldwide Resources (Lagos)

3 Comments

  1. durga rao says:

    COVER LETTER
    I am very keen to work in the offshore oil industry.
    I am willing to start at the bottom and work my way up with in your organization . I am therefore looking for a job as a roustabout.

     I work well as part of a team.
     I like to fit in and get on well with people.
     I find it easy to get on with people.
     I do not mind being away from home for long periods at a time.
     I work well under pressure.
     I can be left un-supervised to get on with my work.
     I am safety conscious about myself.
     I am safety conscious about my fellow workers.
     I can take and carry out orders.
     I can carry my orders out effectively.

     Please find attached the CV for Instrumentation& Control Supervisor/ Inspector/foreman/sr. tech.
     I have Petrochemical, power and gas field experienced.
     My qualification Diploma Engg Instrumentation. {E.C.E}
     I have 10 years Experienced, include gulf experienced also.
     If there is any requirement suitable for me, please contact .
     This is my mobile no. 0096565601691.
     Immediately response.
     This is my Email ID : {[email protected]}
    Thanks & regards
    T. Durga Rao.

  2. mohammad alamgir mallick says:

    Mohammad Alamgir Mallick
    Instrument engineer

    CAREER OBJECTIVE

    • To work in an organization where there is a competitive and healthy environment, and
    Ample prospects for professional growth.
    • 15 years experience as an instrument supervisor / instrument engineer in the
    Maintenance, Construction, pre –commissioning and commissioning fields in various
    Industries like oil & Gas, LNG, Refinery petrochemicals GC plant and fertilizer, with leading
    Global EPC Contractors
    • Principally involved in commissioning and maintenance of plant process distributed
    Control system compressor control system Emergency shutdown system PLCs, electronic
    And smart field instrument ,vendor and client coordination etc. also involved in the construction activities like installation and testing of control room , process trains and
    Utilities instrumentation

    EDUCATIONAL QUALIFICATION

    • Diploma of instrumentation from Community polytechnic college (west Bengal) in 1995
    • SSC from Bihar board in 1991

    AREAS OF EXPERTISE

    • Reviewing specifications, standards, procedures and package documentation.
    • Developed many innovative system and procedures to improve the reliability and
    Availability of the plant instrumentation system
    • Well versed in factory acceptance test (FAT) and site acceptance test (SAT) procedures,
    Procedures.
    • Loop checking, testing and troubleshooting of field instrumentation.
    • Coordination with other department, client, subcontactors and vendor.
    • Thorough knowledge about HSE procedures and responsibilities including risk
    Assessments etc.
    • Well versed in Honeywell TDC 3000, invensys Foxboro, bailey INFI 90 and Yokogawa
    DCS System, Triconex PLC system mark 5 gas turbine control system, compressor antisurge control system and bentem Nevada 3300 vibration monitoring system, boiler
    Management system etc.
    • Well versed in all computer hardware and softwear
    • Well conversant with offshore and onshore oil& gas plant fertilizer plant and LNG
    Plant, with all related safety aspects

    Mohammad Alamgir Mallick
    Instrument engineer
    • PROFESSIONAL EXPERIENCE

    • Project : NCP project in Jubal Saudi Arabia
    Company : Daelim Company (EPC)
    Designation : sr.Instrument engineer
    Duration : 25.01. 2010 to 06.02.2011

    • I have good experience in commissioning & construction, maintenance our area included compressor handled independent men power and instrument. Job logic and sequins checking loop checking calibration, configuration pre commissioning and commissioning and troubleshooting installation cable laying and glanding termination cable tray and conduit work handle

    • Project : Laffan refinery project in Ras Laffan area Doha Qatar
    Company : Gs engineering & Construction Company (EPC)
    Designation : Instrument engineer
    Duration : 25 .11. 2008 to 15.09.2009

    RESPONSIBILITIES

    • Presently working as a Sr. instrument engineer. My task is realization of this multi-discipline project during basic and detailed engineering and construction phases.
    Work in close cooperation with vendor, to translate functional specification into technical solutions. Working with other disciplines as required for the execution of the work in pre-commissioning and commissioning stages.
    • I also review instrumentation / control system specification and vendor documentation, including follow-up of FAT. Updating instrument index with instrumentation / control system related parameters. Cooperating with field implementation (SAT) liaison with third parties, inter discipline coordination etc. I have a thorough knowledge of field instrumentation and DCS control system PLC etc.
    • Project : K.O.C. facilities upgrade relocation
    : GC- 3,4,6,7,8,21, 23, and BS-140,150
    Company : Petrofac international, Kuwait (EPC)
    Designation : Instrument Engineer
    Duration : 20.01.2006 to 25.10.2008

    • I have good experience in commissioning & construction, maintenance our area included compressor handled independent men power and instrument. Job logic and sequins checking loop checking calibration, configuration pre commissioning and commissioning and trouble shooting installation cable laying and glanding termination cable tray and conduits work handling of all kinds of instruments. I was involved in origination review all diagram p&id , ild, cousin effect, termination cable list,treep alarm list , location diagram etc

    Mohammad Alamgir Mallick
    Instrument engineer/supervisor

    • Project : Ruwais ULG/SGO-U.A.E.
    Company : Al Jaber Grinajer-LTa (Alec)
    Designation : Instrument supervisor
    Duration : 13.08.2003 to 24.08.2005

    • Pre-Commissioning, and commissioning and final completion / turnover to client for the multi –billion EPC project. Worked within operational facilities. Ensuring the contractors compliance with all aspect of the worksite HSE plan and policy, permit to work as per client requirements.
    • Supervised instrumentation and control system construction stage to ensure project is carried out in accordance with design, budget and schedule. job also includes interfacing with client representatives ,other contractor etc and coordinating, planning and interfacing of construction activities within a continuous operating plant environment. solving problems and difficulties encountered or elevate it to the appropriate supervisory personnel
    • Maintained daily supervisory checks and records, ensuring that task force is provided safe working condition, proper permit and procedure, to execute the contract as per schedule and target. Also ensure that all quality control checks and tests are completed, with record maintained in accordance with contractor ITPs and method statements
    • Ensure risk assessment has been undertaken and agreed, prior to commencement of any new type of work activity: conduct tool box talks and pre start meetings .contractor progress meeting etc

    • Project : Equate Project Shuaiba Kuwait
    Company : K.C.C.W.L.L.
    Designation : Instrument Supervisor
    Duration : 25.05.1998 to 29.09.1999

    RESPONSIBILITIES
    • Participated in major shutdown overhaul & start-up activates in laffan refinery process 1.2.3
    • Control room carried out shutdown preparation data collection and condition monitoring duties as
    • Assigned by senior engineer. Implement the company HSE policies and procedures etc.

    • Project : R.P.L. Jamnagar Gujarat
    Company : ANI instruments company
    Designation : Instrument Supervisor
    Duration : 20.08.2001 to 15.05.2003
    RESPONSIBILITIES
    • Supervised and participated in preventive troubleshooting and corrective maintenance of
    Control system and instrumentation in process trains steam & gas turbines compressor protection devices / system such as vibration over speed on line QMIs and instrumentation on utilities storage sur & jetties etc. process control system included ICS.DCS.ESD.FIRE&GAS.Etc.

    Mohammad Alamgir Mallick
    Instrument engineer/supervisor

    • I have worked in close co-ordination with my section head to plan, coordinate and direct the work Of instrument technician and contractor to perform all instrument related activities complying with all HSE &PTW requirements also participated in specialized & complex instrument repairs troubleshooting PLC& microprocessor based digital governor systems attended breadown
    Start-up as and when required and provided assistance and support to major & minor projects co-ordinating with other sections and operations planning and scheduling all work related to my section

    • Project : H.P.C.L mahul gaon chembur Mumbai
    Company : Elmatic Engineers pvt ltd
    Designation : Instrument Supervisor
    Duration : 30.02.2000 to 05.02.2001

    RESPONSIBILITIES

    • Carried out day to day preventive and routine maintenance , break down activities for
    • Instrumentation and control system in the covering distributed control system (DCS)
    Programmable logic controllers (PLC) fire & Gas system and also with pressure temperature
    Level, flow, and other measuring and control devices / equipment, control conjunction with section head identifying and ordering required materials, spares and equipment liaised with
    Counterparts in operations to release desired equipment to execute work on site and / or in
    Workshop

    • Ensuring availability of adequate level of consumable and spares in local store and arranged
    For delivery of materials from company stores
    • Assisted and participated in complex maintenance and repairing activities carried out by specialists also participated in major shutdown and overhaul activities
    • Withdrawed necessary tools test equipment and arranging transport and any other support
    • Parts and reassembling device and testing to ensure operability

    • Project : I.P.C.L. Dahej gujrat
    Company : Miraj instrumentation services
    Designation : Instrument Supervisor
    Duration : 30.07.1996 to 23.02.1998

    Mohammad Alamgir Mallick
    Instrument engineer/supervisor

    PERSONAL PROFILE
    Name : MOHAMMAD ALAMGIR MALLLIC
    Father’s name : Mohammad Mujtaba Mallick
    Date of birth : 20.04.1977
    Nationality : Indian
    Religion : Islam (Muslim)
    Marital status : married
    Languages Known : English, Hindi, and Urdu & Arabic

    PASSPORT DETAILS
    Passport No : H3114236
    Date of Issue : 10.05.2009
    Date of Expiry : 09.05.2019
    Place of Issue : Doha Qatar
    Old passport : B0829612

    PRESENT ADDRESS : MOHAMMAD ALAMGIR MALLICK
    Mallick Shahnaz Bano
    C/o Nehal Mallick
    Chawl no 3, room no. 1
    V.B.Nagar, pipe road ,
    Kurla (w), Mumbai-70
    Mobile: 00966595442317/0091 9987373815

    PERMANENT ADDRESS : MOHAMMAD ALAMGIR MALLICK
    S/o Mohammad Mujtaba Mallick
    Villa + Post – Adsar
    District – Jamui
    State – Bihar -811307
    Mobile: 00919934705797
    Mob : 00919973054798

  3. AZIZ.JAMALI says:

    Respected Sir,

    I have been working in Fauji Fertilizer Bin Qasim Limited, as a Sr.Instrument Supervisor at Ammonia Plant. Fauji Fertilizer Bin Qasim Limited (FFBL) is high pressure high temperature largest DAP, UREA(granular) manufacturer chemical plant in Karachi Pakistan. FFBL has its own power generation (52.6 MW) used peak of technology for process automation and control system like DCS, PLC and microprocessor based (SMART) instrumentation that can meet worldwide standards. Consider me if there is a vacancy for me. Please find the attached CV and I hope for a positive reply.

    AZIZ UR REHMAN

    Sr. Instrument Supervisor
    Fauji Fertilizer Bin Qasim Ltd Karachi
    Cell # 0092-3462243209
    Email

    ————————————————————————————————
    Objective:
    To work and prove myself in any challenging environment with an aim to be innovate and discover new horizons in the corporate culture
    Personal Data:
    Father name : Haji Khuda Bakhsh
    Date of birth : 26-06-1967
    CNIC NO : 42000-6151935-5
    Passport no : CZ9159351
    Nationally : Pakistani
    Marital status : Married

    Education Qualification :
    Matriculation science
    Hyderabad. Board

    Diploma in Electronic (Honorary)
    Quaid-E-Azam Campus Lahore

    Certificate of Registration
    All Pakistan Consul skilled workers Lahore.

    Certificate of merit
    1st position in TV servicing course S.B.T.E. Karachi.

    Wireman certificate
    Govt Sindh of Pakistan

    Certificate of participation
    “Jafakash” The art & craft of supervision Vision Vantage consulting (FFBL)

    Certificate of supervisor skilled
    The Learning Organization.

    Best Safety Captain Award
    Fauji fertilizer bin Qasim limited
    Experience:

    16 years experience in Electronic and Pneumatic control system.

    Presently working as Sr Instrument Supervisor in Fauji Fertilizer Bin Qasim LTD Karachi 19th August 1999 till to date.

    Worked in JVC service center Karachi as Electronic Technician
    February 1995 to August 1999.

    Job Experience:
    • Specialist in all kinds of power supplies, control cards, digital and analogue circuits diagrams etc.

    Maintenance & Calibration of following Different process field instrumentation (Electronic & Pneumatic) control systems.

    Control system Bailey Infi 90(DCS).
    Turbine Control system.(GE,Triconix, wood word,)
    Vibration and Monitoring System (Bentley Nevada 7200,3300,3500).
    Burner management system (GE,DURAG,FIRE EYE,HONNYWELL,SACK)
    Analytical Instrumentation.(O2,CO2,H2,PH,Conductivity Explosive meter)
    Safety & Security fire alaram System.
    Electronic Lab standard test Equipments.
    Bagging and shipping Instrumentation.
    Telecommunication System.
    General Electrical Works.

    References:
    Further references will be provided on request.

Leave a Reply